| Andover Controls | ||||
|
The Andover Controls driver (Comport version) supports the Andover AC256/AC8 and the Infinity/Continuum.
Features:
Requires an Andover AC256/AC8/Infinity/Continuum controller with an available comport and terminal mode support. The command line version of the Infinity/Continuum is not required. |
||||
| BACnet | ||||
|
The BACnet driver communicates using the BACnet/IP and PTP protocols.
The BACnet driver supports:
An introduction to the new BACnet features in v1.80 is available here. |
||||
| LonWorks | ||||
|
The LonWorks driver uses the Echelon OpenLDV Installer available free of charge at:
http://www.echelon.com/products/development/openldv/default.htm The Echelon PCCx, PCLTAxx or SLTAx interfaces are currently supported. Catalyst Pro will automatically discover all devices on an existing network and import the points from each device. Please note that Catalyst Pro is not a network setup tool. It will communicate with devices that have not been configured with a network tool (for example, a stand-alone Trane panel) but it does not provide a way to make network variable connections between devices. There are no royalties, tickets or per-point charges when using this driver. The LonWorks driver supports:
|
||||
| OPC | ||||
|
The OPC Server driver allows Catalyst Pro to connect to any standard OPC server. Using this driver allows
placing control points from virtually any device on a Catalyst Pro graphic display. Please note that you
must have an OPC server program for a given device already installed.
The OPC driver supports:
|
||||
| ModBus | ||||
|
The ModBus driver allows placing points from any compatible RS-232/RS-485 ModBus slave device using the
RTU or ASCII protocol on Catalyst Pro graphic displays. Reading/writing of outputs, reading of inputs and
reading/writing of Holding registers and Input registers are supported.
The ModBus driver supports:
|
||||
| Intelligent Lighting Controls | ||||
|
The Intelligent Lighting Controls (Reliant Relay Co.) driver supports the Quanta Elite panels using the
standard ILC protocol or the Master/Slave protocol over an RS-232 or RS-485 connection.
All standard Catalyst Pro features are supported. Trending is supported by the driver itself. The driver will collect historical data at 15 minute intervals when it is left running and connected to the panels. |
||||